SuggestSoft.com

Ansi B18 2 1

MITCalc - Bolted connection 1.22

MITCalc - Bolted connection 1.22: Design and strength check of a prestressed bolt connection 2D CAD systems (AutoCAD, AutoCAD LT, IntelliCAD, TurboCAD…) The calculations use data, procedures, algorithms and data from specialized literature and standards ANSI, ISO, DIN. Used standards: ANSI B1.1, ANSI 273, ANSI B18.2.1, ANSI B18.2.2, ANSI B18.3, ANSI B18.6.2, ANSI B18.6.3, ANSI B18.22.1, ISO 273, ISO 1207, ISO 4016, ISO 4032, ISO 4035, ISO 4762, ISO 8738, VDI 2230. This module is a part of MITCalc - Mechanical and Technical Calculation






MITCalc - Pinned couplings 1.17: Geometric design and strength check of couplings using pins and clevis pins
MITCalc - Pinned couplings 1.17

SI B18.8.1, ANSI B18.8.2, ISO 2338, ISO 2339, ISO 2340, ISO 2341, ISO 8733, ISO 8734, ISO 8735, ISO 8739, ISO 8740, ISO 8741, ISO 8742, ISO 8743, ISO 8744, ISO 8745, ISO 8746, DIN 1, DIN 7, DIN 1443, DIN 1444, DIN 1470, DIN 1471, DIN 1472, DIN 1473, DIN 1474, DIN 1475, DIN 1476, JIS B 1352, JIS B 1354, JIS B 1355, BS EN 22339, BS EN 22340, BS EN 22341, CSN EN 22339, CSN EN 22340, CSN EN 22341. This module is a part of MITCalc - Mechanical and Technical

pins, joint, pinned couplings, clevis pin, coupling





MITCalc - Roller Chains Calculation 1.19: Design and strength check of roller chain transmission
MITCalc - Roller Chains Calculation 1.19

The calculation is designed for a geometrical design and strength check of common chain transmissions using roller chains. Application is developed in MS Excel, is multi-language, supports Imperial and Metric units and solves the following tasks: - Selection of a power suitable type of chain. - Selection of an optimum transmission alternative regarding power, geometry and weight. - Calculation of geometric, strength, safety and operational parameters. - Calculation of power parameters and axis loads. - Support of 2D CAD (AutoCAD, AutoCAD LT, IntelliCAD, Ashlar Graphite, TurboCAD) and 3D CAD in full calculation package (Autodesk Inventor, SolidWorks, SolidEdge, Pro/E). The application includes corresponding databases of roller chains. The calculations use data, procedures, algorithms and data from ANSI/ASME, ACA (American Chain Association) ISO, DIN, BS and JIS. Used standards: ANSI/ASME B29.1M (Dec2001), ANSI/ASME B29.3, DIN 8187, DIN 8181, DIN 8181, DIN 8164, DIN 8150, ISO R606, ISO 1275, BS 228, JIS B1801, JIS B1803.This module is a part of MITCalc - Mechanical and Technical Calculation Package for gear, belt and chain drives, springs, beam, shaft, bolt connection, shaft connection, tolerances and many others

chain transmission, ansi asme b29 3, strength check, din 8187, design, chain, ansi asme b29 1m, din 8164, din 8181, roller chain



Upgrade PST to Outlook 2007 2.0: Increase PST file size limit and upgrade PST to Outlook 2007 with PST Upgrade
Upgrade PST to Outlook 2007 2.0

2007 – Upgrade PST to Unicode and Unicode to ANSI PST with the using of PST Upgrade software, a product of SysTools. Software allows users to convert ANSI to Unicode Outlook and convert Unicode PST to ANSI PST. Unicode to ANSI converter can convert upper version PST files (2003/2007 and 2010) to lower version PST files (XP/2000 and 2002). To increase PST file size limit and convert Outlook PST to Unicode PST you must choose always PST Upgrade software

unicode to ansi conversion, upgrade pst to unicode, ansi to unicode outlook, convert ansi pst to unicode, unicode to ansi converter, ansi to unicode pst, increase pst file size limit, convert outlook pst to unicode, upgrade pst to outlook 2007



ANSI to Unicode Conversion 2.5: Upgrade Outlook PST File Quickly  with ANSI to Unicode Conversion Utility
ANSI to Unicode Conversion 2.5

ANSI to Unicode format using an Outlook Upgrade PST tool. This ANSI PST to Unicode PST conversion helps you to open Outlook mailboxes (PST) into newer Outlook applications (Outlook 2003, Outlook 2007, and Outlook 2010). You can easily convert Outlook 2007 PST to Outlook XP and convert Outlook 2000 PST to Outlook 2000 PST to Outlook 2007 with this Outlook ANSI to Unicode conversion tool. If Outlook ANSI PST crosses the limit of 2GB then your PST will

upgrade outlook pst file, convert, folders, outlook, ansi to unicode format, file, outlook upgrade pst, ansi to unicode conversion, 2007, upgrade, 2000, outlook ansi to unicode



No Image
ACiDDraw ANSI Editor 1.25r

A full featured ANSI text editing utility which lets you create and manipulate ANSI/ASCII images. ACiDDraw now supports ANSI, ASCII, Pascal, C, ASM, COM, BIN and PCBOARD save formats. It also features four editing pages at 1,000 lines each, 160-column editing mode, VGA previewing, text justification, and more.

dos editor, aciddraw, vga preview, screen editor, text editor, pcboard support, acid draw, ascii editor, acid productions, ansi editor



NIST (ANSI/NIST-ITL 1-2000) library 2.5: Reads NIST (ANSI/NIST-ITL 1-2000) format.
NIST (ANSI/NIST-ITL 1-2000) library 2.5

NIST (ANSI/NIST-ITL 1-2000) library. Version 1.0. Cognaxon NIST (ANSI/NIST-ITL 1-2000) library reads and extracts NIST (ANSI/NIST-ITL 1-2000) file format. The advantage of NIST files is the ability to contain multiple images and other types of data about the person in one single file, which simplifies biometric data exchange between participating parties. For latest version and more information please visit: http://www.cognaxon.com

ansi nist itl 1 2000, wavelet scalar quantization, image converter, nist


More Results: 1  2  3  

World IT News